气体增压、载氢系统400MPa、英国Gas Boosting Systems
Principal Specification
Maximum working pressure 400 MPa
Pre-charge pump STANSTED AO-9512C
Pre-charge pressure 40 MPa
High Pressure generation STANSTED model 085/20 intensifier
Hydraulic drive pump STANSTED AO-0812W
Stroke and recharge time 3 minutes (approx.)
Displacement per intensifier stroke 45 ml approx.
Working fluid Hydrogen, Nitrogen, Argon, helium or other SFP approved gas
Ramp Rate control By manual adjustment of hydraulic drive pump air drive pressure
Decompression Manual control
Pressure measurement Pressure indicator on hydraulic drive pressure circuit scaled by intensification ratio (20:1) to indicate the high pressure in the pressure vessel.
Note a high pressure transducer and display in the high pressure circuit is optionally available, if scaled pressure is not acceptable.
Pressure control Manual. System includes an adjustable relieve valve on the drive hydraulics to enable pressure to be limited. To within safe operating pressure range.
General operation and control Manual operation
Outlet pressure connection 1/4” HP port (9/16” x 18 tpi)
Foot print pressure and control module 0.8m x 0.6m
Weight 150 kg approximate
Electrical Power None.
Compressed air/gas drive 6 barg min, 10 barg max. Consumption 150 Nl/min
Process gas (H2 or other) supply 300 bar maximum 100 bar minimum
Contract client