Gas Boosing Systems, 700MPa Hydrogenation System,Hydrogen Pressure Generation System
SYSTEM SPECIFICATION
Design pressure 400 MPa
Working Pressure 440 MPa
Working Fluid Hydrogen, Nitrogen, Argon, Helium or other SFP approved gas
HP gas min temperature at inlet -20°C HP gas max temperature at inlet +30°C
HP outlet Connection Ø3/16" HP (SFP type)
HP system mounting Painted frame
Approximate Dimensions 750mm deep 1500mm high 1500mm wide
Initial Compression Two stage TC10C gas booster, contaminant free
Inlet pressure 3.5 MPa bar regulated (integral regulator)
Outlet pressure 35 MPa
Second stage compression Hydraulically driven intensifier, contaminant free Dive pump system TC10/1212H
MWP 520 bar
Fluid reservoir 10 lt.
2nd stage Intensifier 085/20
MWP 700 MPa
System Flow rate 3.5 - 35 MPa 30 Nl/min
35 -700 MPa 15 Nl/min max.
Decompression System Automatic with manual override
Stop valve backed by a capillary metering device Emergency manual metering valve.
Pressure measurement 0-400 MPa strain gauge transducer
Control Mounted on module
Push buttons & indicator lights Digital pressure displays
PLC data access unit & interface keypad
Signal communications USB connection Operator set parameters
Cycle pressure 0-400 MPa
Pressure function Pressure maintain or Knock off
Dwell at pressure Holds until released by operator
Rupture assembly 400 MPa
Services Electrical 3ph 400/440V 50 Hz Loading 2 kW
Pneumatic 0.5 MPa min.
1 MPa max.
Flow rate approx. 30 Nl/min
Supply Gas 3.5 MPa min
30 MPa max
System will include an integral pressure regulator to reduce pressure to booster inlet pressure of 35 MPa
Contract client